AH05 Pipe Inspection Camera CE EMC Certificate – CKEYS260120058
Document Details
| Product Model | AH05 |
|---|---|
| Model Description | AH05 Borescope (Pipe Inspection Camera), evaluated with an A-0718 AC power adapter rated at 100–240V AC input and 5V DC, 2.1A output. |
| Document Type | CE EMC |
| Certificate Number | CKEYS260120058 |
| Certificate Holder / Applicant | Shenzhen Yonghengfeng Intelligent Device Co., Ltd. |
| Issuing Organization | Guangdong KEYS Testing Technology Co., Ltd. |
| Document Scope / Standards | CE EMC Certificate of Conformity for the AH05 Borescope, marketed as an AH05 Pipe Inspection Camera, under Directive 2014/30/EU. The associated 50-page report RKEYS260113386 records PASS results for conducted and radiated emissions, voltage fluctuations and flicker, ESD, radiated RF, EFT, surge, conducted RF, power-frequency magnetic field and voltage dip immunity. Harmonic current emissions are marked N/A. The evaluation used the A-0718 power adapter in normal working mode at AC 230V/50Hz. |
| Issue Date | 20 January 2026 |
| Related Test Report | RKEYS260113386 |
What This Document Is
This Certificate of Conformity documents the electromagnetic compatibility (EMC) assessment of the AH05 Borescope, marketed as the AH05 Pipe Inspection Camera, under EU Directive 2014/30/EU.
The supporting 50-page laboratory report references EN 55011:2016/A2:2021, EN IEC 61000-6-2:2019, EN IEC 61000-3-2:2019/A2:2024 and EN 61000-3-3:2013/A2:2021/AC:2022-01.
The report provides conducted and radiated emission measurements, power-quality assessment results, electromagnetic immunity observations and photographs of the tested configuration. The laboratory recorded PASS verdicts for the applicable assessments, while harmonic current emissions were classified as Not Applicable.
The certificate relates to the submitted sample and does not constitute ongoing production certification or independent confirmation of compliance with every EU product requirement.
What This Certificate Covers
The tested AH05 was operated in normal working mode using an A-0718 external power adapter. The adapter is identified with a 100–240V AC, 50/60Hz input and a 5V DC, 2.1A output. The principal laboratory measurements were performed using an AC 230V, 50Hz supply.
Conducted and Radiated Emission Results
Mains-port conducted emissions received a PASS verdict under EN 55011. The report contains separate line and neutral measurements, including recorded emission levels, applicable limits and compliance margins.
Radiated emissions were assessed from 30 MHz to 1 GHz at a 3-meter measurement distance, using horizontal and vertical antenna polarizations.
The vertical-polarization measurements included a recorded emission level of 35.21 dBμV/m at 57.89 MHz, against a 40.00 dBμV/m limit. The resulting compliance margin was 4.79 dB, with a PASS verdict.
The report also records passing voltage fluctuation and flicker results. Harmonic current emissions were classified as Not Applicable because the equipment power was below the stated 75W threshold.
Electromagnetic Immunity Results
Electrostatic discharge testing covered ±8kV air discharge and ±4kV contact discharge. The detailed results include tests on enclosure-related locations and coupling planes, with passing observations.
Radiated RF immunity was assessed from 80 MHz to 1 GHz at 3 V/m, with horizontal and vertical antenna polarizations applied to different sides of the equipment. The report records Performance Criterion A.
The laboratory additionally reported passing results for electrical fast transients, surge disturbances, conducted RF immunity, power-frequency magnetic fields and voltage dips or interruptions.
The documented surge assessment included a ±1kV line-to-neutral test. Other surge connections were marked not applicable in the detailed results.
These findings represent the tested AH05 electrical configuration and operating conditions. They should not be extended automatically to different adapters, modified electronics or revised cable assemblies.
Why It Matters for Buyers
For EU importers and pipe inspection equipment distributors, this certificate and its supporting report provide technical evidence of the AH05’s electromagnetic emission and immunity performance under the documented laboratory conditions.
The external adapter specification is an important verification point. Buyers should compare the power supply, connector arrangement, control electronics and tested hardware with the configuration intended for delivery.
The recorded emission margins and immunity results provide more detailed evidence than the certificate alone. They allow technical purchasing teams to review individual test results and identify the conditions under which the equipment was assessed.
The EMC evaluation does not establish waterproof performance, camera image quality, cable durability, electrical safety or inspection accuracy.
For OEM/ODM projects, changes to power adapters, display electronics, circuit boards, cable arrangements or other EMC-relevant components may require updated technical assessment.
QBH can assist importers, distributors and private-label customers in comparing their requested AH05 configuration with the available EMC documentation and identifying whether further evidence or testing is required.
Related Certifications & Resources
Find CE, FCC, RoHS and related compliance records for QBH borescopes, pipe inspection cameras, diagnostic tools and cleaning equipment. Select your product family, then check the documents available for your exact model and configuration.

Pipe Inspection Cameras
Pipe camera compliance documents

A/C Evaporator Cleaning Equipment
Cleaning equipment certifications

Automotive Diagnostic Tools
Tester and diagnostic tool records