AV7823 Car Visual AC Cleaning Gun CE EMC Certificate – 2016NT12120549
Document Details
| Product Model | AV7823 |
|---|---|
| Model Description | AV7823 Visual Cleaning Borescope, marketed as a Car Visual AC Cleaning Gun, evaluated in running mode with DC 5V power supplied through an AC adapter. |
| Document Type | CE EMC |
| Certificate Number | 2016NT12120549 |
| Certificate Holder / Applicant | Shenzhen QBH Technology Development Co., Ltd. |
| Issuing Organization | Shenzhen NTEK Testing Technology Co., Ltd. |
| Document Scope / Standards | CE EMC conformity certificate for the AV7823 Visual Cleaning Borescope (Car Visual AC Cleaning Gun), assessed under Directive 2014/30/EU. The associated 57-page report records PASS results for Class B conducted and radiated emissions, voltage flicker, ESD, radiated RF, EFT, surge, conducted RF, magnetic field and voltage dip immunity. Harmonic current emissions and radiated emissions above 1 GHz are marked N/A. Findings apply to the evaluated sample. |
| Issue Date | 9 January 2017 |
| Related Test Report | NTEK-2016NT12120549E |
What This Document Is
This Certificate of EMC Compliance documents the electromagnetic compatibility assessment of the AV7823 Visual Cleaning Borescope, also marketed as a Car Visual AC Cleaning Gun, under European Directive 2014/30/EU.
The certificate is supported by a 57-page laboratory report covering electromagnetic emissions, power-related disturbances and immunity performance. The assessment references EN 55022:2010+AC:2011, EN 55024:2010+A1:2015, EN 61000-3-2:2014 and EN 61000-3-3:2013.
The laboratory recorded passing verdicts for the applicable emission and immunity assessments. The certificate provides historical technical evidence for the tested AV7823 sample and should be reviewed together with its supporting report.
What This Certificate Covers
The evaluated AV7823 was operated in Running mode using a DC 5V supply from an external AC adapter. The report identifies an 80 cm unshielded cable fitted with a ferrite core as part of the representative test configuration.
Emission and Power-Quality Results
Conducted emissions were assessed from 150 kHz to 30 MHz, with passing Class B results recorded for the line and neutral measurements. Radiated emissions also passed the applicable Class B limits over 30 MHz to 1 GHz, including horizontal and vertical antenna measurements.
The voltage fluctuation and flicker assessment recorded a short-term flicker value (Pst) of 0.020 against a limit of 1.00, and a long-term flicker value (Plt) of 0.021 against a limit of 0.65. Both results passed. The report also recorded passing steady-state and maximum voltage-change results.
Harmonic current emission limits were considered not applicable because the equipment’s active input power was below 75W. Radiated emission testing above 1 GHz was also marked Not Applicable under the report’s stated measurement-range criteria.
Electromagnetic Immunity Results
Electrostatic discharge testing included ±8 kV air discharge and ±4 kV contact discharge, with passing results at the applicable test locations. These locations included the display, buttons, enclosure-related metal parts and USB port.
Radiated RF immunity testing passed at 3 V/m over 80 MHz to 1 GHz, with Performance Criterion A.
The report additionally records passing results for electrical fast transients, surge disturbances, conducted RF immunity, power-frequency magnetic fields and voltage dips or interruptions under their respective test conditions.
These findings apply to the evaluated AV7823 configuration and should not be extended automatically to redesigned electronics, different adapters or altered cable arrangements.
Why It Matters for Buyers
For European importers and automotive equipment distributors, the report provides detailed evidence of the AV7823’s evaluated electromagnetic emission and immunity performance.
The power arrangement and cable configuration are particularly important when comparing the tested sample with the equipment supplied for automotive air-conditioning cleaning applications. Buyers should confirm the adapter, ferrite-equipped cable, display electronics and other relevant components before relying on the original results.
The documented ESD, RF immunity and power-disturbance assessments also provide useful information for reviewing the electronic system’s behavior under the specified laboratory conditions. They do not, however, establish cleaning performance, liquid resistance or electrical safety compliance.
For OEM/ODM projects, changes to the power adapter, control electronics, display module, cable shielding or ferrite configuration may affect the applicability of the existing EMC evidence.
QBH can assist distributors and private-label buyers in comparing their requested AV7823 configuration with the available laboratory documentation and identifying where updated technical evidence or additional testing may be required.
Related Certifications & Resources
Find CE, FCC, RoHS and related compliance records for QBH borescopes, pipe inspection cameras, diagnostic tools and cleaning equipment. Select your product family, then check the documents available for your exact model and configuration.

Pipe Inspection Cameras
Pipe camera compliance documents

A/C Evaporator Cleaning Equipment
Cleaning equipment certifications

Automotive Diagnostic Tools
Tester and diagnostic tool records