FT03 Air Quality Detector FCC Part 18 Verification – WTH20H10080291E
Document Details
| Product Model | FT03 |
|---|---|
| Model Description | FT03 Air Quality Detector with a documented DC 3.7V, 0.05A, 0.185W power configuration and charge/discharge operating modes. |
| Document Type | FCC Other |
| Certificate Number | WTH20H10080291E |
| Certificate Holder / Applicant | Shenzhen Yonghengfeng Intelligent Device Co., Ltd. |
| Issuing Organization | Shenzhen Hongcai Testing Technology Co., Ltd. |
| Document Scope / Standards | FCC Part 18 Verification of Conformity for the FT03 Air Quality Detector. The associated 15-page test report records a Compliant verdict for radiated emissions under FCC Section 18.305(b), measured from 30 MHz to 1 GHz at a 3-meter distance. Conducted emissions under Section 18.307(b) are marked Not Applicable. The evaluation identifies a DC 3.7V, 0.05A, 0.185W sample. The applicability of FCC Part 18 to the finished product requires independent verification. |
| Issue Date | 5 November 2020 |
| Related Test Report | WTH20H10080291E |
What This Document Is
This Verification of Conformity document records an electromagnetic emission assessment of the FT03 Air Quality Detector against FCC 47 CFR Part 18, as referenced in the original laboratory documentation.
The associated 15-page test report was prepared using ANSI C63.4:2014 and FCC/OST MP-5 measurement references. It includes the evaluated equipment specification, operating modes, radiated emission measurements and photographs of the tested device.
The laboratory reported a Compliant verdict for radiated emissions. This document represents historical testing evidence against the stated requirements. It is not an FCC Certification grant, an assigned FCC ID or independent confirmation that Part 18 is the correct regulatory framework for the finished FT03 product.
What This Certificate Covers
The evaluated FT03 Air Quality Detector is described with a DC 3.7V input, rated current of 0.05A and power consumption of 0.185W.
The report identifies two operating modes: TM1 (Charge) and TM2 (Discharge). The laboratory selected operating conditions intended to capture the equipment’s highest possible electromagnetic emission levels.
Radiated emissions were evaluated under FCC Section 18.305(b) using a 3-meter measurement setup. The recorded frequency range extended from 30 MHz to 1 GHz.
The report provides separate horizontal and vertical antenna-polarization plots, with frequency-specific emission readings and the applicable laboratory limits. The overall radiated emission assessment was reported as Compliant.
Conducted emissions under FCC Section 18.307(b) were marked Not Applicable. No separate passing verdict for conducted emissions is established by this report.
The report also contains photographs of the evaluated device, including its front display, rear enclosure, charging port, internal battery and printed circuit board. These records help identify the hardware configuration represented by the historical test evidence.
The assessment does not establish electromagnetic immunity, electrical safety, sensor measurement accuracy or compliance with requirements outside its documented scope.
Why It Matters for Buyers
For US importers and distributors, this report provides historical laboratory evidence of the FT03’s radiated emission performance under the stated test conditions.
The enclosure and internal PCB photographs help purchasing teams compare the evaluated product with the currently supplied version. Differences in the battery, charging circuit, display electronics or internal board layout may affect whether the original evidence remains relevant.
Because the report references FCC Part 18, the equipment classification and applicable FCC authorization procedure should be confirmed before using these documents for US market entry.
The verification document does not replace the compliance information, responsible-party details or other records required under the applicable FCC procedure.
For OEM/ODM projects, changes to the power supply, charging interface, sensor electronics or PCB design may require additional emission assessment.
QBH can assist distributors and private-label customers in reviewing the available FT03 documentation, comparing the tested hardware with their requested configuration and identifying where updated evidence or further verification is required.
Related Certifications & Resources
Find CE, FCC, RoHS and related compliance records for QBH borescopes, pipe inspection cameras, diagnostic tools and cleaning equipment. Select your product family, then check the documents available for your exact model and configuration.

Pipe Inspection Cameras
Pipe camera compliance documents

A/C Evaporator Cleaning Equipment
Cleaning equipment certifications

Automotive Diagnostic Tools
Tester and diagnostic tool records