KS02 Handheld Endoscope CE EMC Certificate – HCT17KR-1834E
Document Details
| Product Model | KS02 |
|---|---|
| Model Description | KS02 Handheld Endoscope, identified with a DC 6V rated input in the EMC test report. The radiated emission measurement records specify DC 5V as the test voltage. |
| Document Type | CE EMC |
| Certificate Number | HCT17KR-1834E |
| Certificate Holder / Applicant | Shenzhen QBH Technology Development Co., Ltd. |
| Issuing Organization | Shenzhen Hongcai Testing Technology Co., Ltd. |
| Document Scope / Standards | CE EMC conformity certificate for the KS02 Endoscope under Directive 2014/30/EU. The associated 21-page report HCT17KR-1834E records PASS results for Class B radiated emissions, electrostatic discharge immunity and radiated RF immunity. Other listed tests are marked Not Applicable. Results relate to the evaluated sample and documented test conditions. |
| Issue Date | 24 November 2017 |
| Related Test Report | HCT17KR-1834E |
What This Document Is
This CE Certificate of Conformity records the electromagnetic compatibility (EMC) assessment of the KS02 Endoscope under the European EMC Directive 2014/30/EU.
The certificate is supported by a 21-page measurement and test report covering electromagnetic disturbance emissions and immunity performance. The report references EN 61000-6-3 for emission requirements and EN 61000-6-1 for immunity requirements, together with the additional standards identified in the certification documents.
The laboratory recorded passing results for the applicable radiated emission, electrostatic discharge and radiated RF immunity assessments. The certificate states that the applicant may issue a Declaration of Conformity and apply CE marking in accordance with applicable European Union rules.
This laboratory certificate should be reviewed together with its supporting report and is not a substitute for the manufacturer’s EU Declaration of Conformity.
What This Certificate Covers
The evaluation concerns the KS02 Endoscope identified in the test report with a rated DC 6V input. The radiated emission measurement records separately identify DC 5V as the test voltage, so the exact power configuration should be confirmed against the original tested sample.
Radiated electromagnetic emissions were assessed under EN 61000-6-3 Class B limits. The report records a PASS verdict for measurements over 30 MHz to 1 GHz at a 3-meter test distance, with horizontal and vertical antenna polarizations.
Electrostatic discharge immunity under EN 61000-4-2 also passed. The assessment included air discharge up to ±8 kV and direct and indirect contact discharge at the applicable ±4 kV levels. The recorded performance met Criterion B, including the ability to recover normal operation following permitted temporary disturbances.
Radiated radio-frequency immunity testing under EN 61000-4-3 received a PASS verdict. The equipment was evaluated over 80 MHz to 1 GHz at a field strength of 3 V/m with 80% amplitude modulation at 1 kHz. The observed performance met Criterion A for the tested orientations.
The report identifies mains conducted emissions, harmonic current emissions, voltage fluctuations, electrical fast transients, surge immunity and several other assessments as Not Applicable. These items should not be represented as independently tested and passed.
The findings relate to the evaluated sample and the specified laboratory conditions. They do not automatically establish equivalent EMC performance for later production revisions or modified KS02 configurations.
Why It Matters for Buyers
For European importers and distributors, this certificate and its supporting report provide historical technical evidence of the KS02’s electromagnetic emission and immunity performance.
The Class B emission findings help buyers review the electromagnetic disturbances generated by the evaluated equipment. The ESD and radiated RF immunity results provide additional evidence of performance under specified external electromagnetic disturbances.
Before relying on this documentation, buyers should verify that the supplied KS02 matches the tested electronic design, power configuration and relevant accessories. The difference between the rated DC 6V input and the DC 5V radiated test condition should also be clarified.
Because the assessment was performed in 2017, importers should check whether the referenced standards and technical documentation remain suitable for the current product configuration and applicable EU requirements.
For OEM/ODM projects, modifications to circuit boards, display electronics, power arrangements, cables or other components affecting electromagnetic performance may require updated test evidence.
QBH can assist importers, distributors and private-label buyers in reviewing the available EMC documentation, verifying configuration consistency and identifying where further compliance assessment may be needed.