WT06 Brake Fluid/Coolant Boiling Point Tester FCC Verification – WTH20H12098407E
Document Details
| Product Model | WT06 |
|---|---|
| Model Description | WT06 Brake Fluid/Coolant Boiling Point Tester, evaluated in normal operating mode with documented DC 12V input and output specifications. |
| Document Type | FCC Other |
| Certificate Number | WTH20H12098407E |
| Certificate Holder / Applicant | Shenzhen Yonghengfeng Intelligent Device Co., Ltd. |
| Issuing Organization | Shenzhen Hongcai Testing Technology Co., Ltd. |
| Document Scope / Standards | FCC Part 18 Verification of Conformity for the WT06 Brake Fluid/Coolant Boiling Point Tester. The associated 16-page report WTH20H12098407E records a Compliant verdict for radiated emissions under FCC Section 18.305(b), measured from 30 MHz to 1 GHz at a 3-meter distance. The equipment is described with DC 12V input, 12A, 150W and DC 12V, 10A output ratings. No independent conducted-emission verdict is listed in the test summary. Applicability of Part 18 and the EN 55011 Class B plots requires review. |
| Issue Date | 23 December 2020 |
| Related Test Report | WTH20H12098407E |
What This Document Is
This Verification of Conformity document records an electromagnetic emission assessment of the WT06 Brake Fluid/Coolant Boiling Point Tester against FCC 47 CFR Part 18, as referenced in the original laboratory documentation.
The supporting 16-page test report was prepared with reference to ANSI C63.4:2014 and FCC/OST MP-5. It contains the equipment’s electrical specifications, radiated emission measurements, laboratory test arrangements and photographs of the submitted tester.
The laboratory recorded a Compliant verdict for radiated emissions under the stated requirements. This document represents historical test evidence for the evaluated equipment, not an FCC Certification grant or confirmation that all requirements for US market authorization have been fulfilled.
What This Certificate Covers
The WT06 is identified in the report with a DC 12V input rated at 12A and 150W, together with a DC 12V output rated at 10A.
Unlike low-power handheld diagnostic tools, this configuration includes a higher-current power arrangement. The assessment therefore needs to be considered in relation to the tested electrical hardware and external connections.
The report identifies TM1 (Normal Operation) as the evaluated operating mode. The radiated emission measurement plots further describe the equipment as operating at boot.
Radiated emissions were evaluated over 30 MHz to 1 GHz using a 3-meter measurement arrangement. The report includes separate horizontal and vertical antenna-polarization results, frequency-specific readings and compliance margins.
The laboratory recorded an overall Compliant verdict for the radiated emission assessment under FCC Section 18.305(b).
The measurement plots on pages 10–11 identify EN 55011 Class B limits, while the report’s regulatory scope refers to FCC Part 18. The relationship between these references should be clarified with the issuing laboratory before making broader regulatory claims.
No independent conducted-emission result is listed in the report’s test summary. The available document therefore does not establish a separate passing conclusion for that assessment.
The report also provides photographs of the evaluated WT06, including its display, control buttons, external cables, electrical connection clips and internal printed circuit boards.
These records help identify the hardware configuration represented by the original test evidence. The findings do not establish brake fluid boiling-point measurement accuracy, coolant testing accuracy, electrical safety or electromagnetic immunity performance.
Why It Matters for Buyers
For US importers and automotive diagnostic equipment distributors, the report provides historical laboratory evidence of the WT06’s radiated emission performance under the documented conditions.
The DC 12V electrical configuration and external connection accessories are particularly relevant when comparing the tested sample with the version being supplied.
Buyers can review the product and internal PCB photographs to check whether the enclosure, wiring, display and electronic assemblies correspond to the requested hardware configuration.
Before relying on these documents for US distribution, buyers should verify the applicable FCC equipment classification, test-limit references and required authorization procedure.
For OEM/ODM projects, changes to the power circuitry, external connection cables, PCB layout, display electronics or other electromagnetic emission-related components may affect the relevance of the historical test evidence.
QBH can assist distributors and private-label customers in reviewing the available WT06 documentation, comparing the tested configuration with their purchasing specifications and identifying where further laboratory clarification or updated testing may be required.
Related Certifications & Resources
Find CE, FCC, RoHS and related compliance records for QBH borescopes, pipe inspection cameras, diagnostic tools and cleaning equipment. Select your product family, then check the documents available for your exact model and configuration.

Pipe Inspection Cameras
Pipe camera compliance documents

A/C Evaporator Cleaning Equipment
Cleaning equipment certifications

Automotive Diagnostic Tools
Tester and diagnostic tool records