WX02 Atomization Disinfection Machine CE EMC Certificate – BCTC2005001178C

Certificate of Compliance with ornate blue border and BCTC logo, for Atomization Sterilizer Disinfection Machine by Shenzhen Yonghengfeng Intelligent Device Co., Ltd.

Document Details

Product ModelWX02
Model DescriptionWX02 Atomization Sterilizer Disinfection Machine, rated for AC 110V/60Hz and AC 230V/50Hz, with EMC testing documented in working mode at AC 230V/50Hz.
Document TypeCE EMC
Certificate NumberBCTC2005001178C
Certificate Holder / ApplicantShenzhen Yonghengfeng Intelligent Device Co., Ltd.
Issuing OrganizationShenzhen BCTC Testing Co., Ltd.
Document Scope / StandardsCE EMC Certificate of Compliance for the WX02 Atomization Sterilizer Disinfection Machine under Directive 2014/30/EU. The associated 35-page report BCTC2005001178E records PASS results for mains disturbance voltage, radiated disturbance, harmonic current, voltage fluctuations and flicker, ESD, EFT, surge, conducted RF immunity and voltage dips. Radiated RF immunity and certain other emission tests are marked N/A. The sample was assessed primarily at AC 230V/50Hz in working mode.
Issue Date26 May 2020
Related Test ReportBCTC2005001178E

What This Document Is

This Certificate of Compliance documents the electromagnetic compatibility (EMC) assessment of the WX02 Atomization Sterilizer Disinfection Machine under European Directive 2014/30/EU.

The certificate is supported by a 35-page laboratory test report covering conducted and radiated electromagnetic disturbances, harmonic current emissions, voltage fluctuations and selected immunity assessments. The evaluation references EN 55014-1:2017, EN 55014-2:2015, EN 61000-3-2:2019 and EN 61000-3-3:2019.

The laboratory recorded an overall PASS conclusion for the submitted WX02 sample. The certificate and report provide historical EMC testing evidence, rather than confirmation of ongoing production conformity or compliance with unrelated product requirements.

What This Certificate Covers

The evaluated WX02 is described with rated AC supplies of 110V/60Hz and 230V/50Hz. The principal EMC measurements were conducted in working mode at AC 230V/50Hz.

The report also identifies a detachable shielded cable with a ferrite ring. This configuration is relevant when comparing the tested equipment with production units or customized versions.

Electromagnetic Emission Results

Mains-port disturbance voltages were evaluated from 150 kHz to 30 MHz. The laboratory recorded PASS results and provided separate line and neutral measurement plots with frequency-specific readings and compliance margins.

Radiated disturbances were assessed from 30 MHz to 1 GHz at a 3-meter measurement distance. Horizontal and vertical antenna measurements were recorded, with PASS conclusions under the applicable EN 55014-1 limits.

Harmonic current emissions and voltage fluctuations and flicker also received PASS results. The report includes harmonic measurements and voltage-fluctuation records obtained under the documented AC supply conditions.

Discontinuous disturbance, disturbance power and the listed magnetic-field assessments were marked Not Applicable rather than independently tested and passed.

Electromagnetic Immunity Results

Electrostatic discharge testing included ±4 kV contact discharges and ±8 kV air discharges, with additional indirect discharges applied through horizontal and vertical coupling planes. The report records passing performance for the evaluated test points.

The laboratory also recorded passing results for electrical fast transients, surge disturbances and injected-current RF immunity. The reported surge test levels included ±1 kV between line and neutral and ±2 kV between supply conductors and protective earth.

Voltage dip and interruption testing received an overall PASS verdict. However, the detailed results record temporary loss of operation during certain voltage-reduction conditions, followed by automatic recovery when the test ended.

This recovery behavior is part of the recorded immunity performance and should not be described as uninterrupted operation throughout every disturbance.

Radiated RF electromagnetic-field immunity was marked Not Applicable in the test summary. The separate test-mode description does not establish an independent passing result for that item.

The findings apply to the tested WX02 sample and the documented configuration. Changes to the power supply, internal control electronics, cable arrangement or other EMC-relevant components may require further assessment.

Why It Matters for Buyers

For European importers and distributors, the report provides documented evidence of the WX02’s electromagnetic emissions and immunity performance under the specified laboratory conditions.

The AC supply configuration, ferrite-equipped cable and power-related test results are particularly useful when checking whether the delivered equipment corresponds to the evaluated sample.

The voltage dip results also provide buyers with information about the equipment’s observed recovery behavior during electrical disturbances. This can support technical documentation reviews, although it does not establish performance in every operating environment.

Before relying on the certificate, buyers should verify the supplied hardware configuration, applicable EU Declaration of Conformity and any additional requirements relevant to the intended use of the equipment.

For OEM/ODM projects, changes to the power cord, ferrite arrangement, internal circuitry, control components or other electromagnetic characteristics may affect the relevance of the existing report.

QBH can assist distributors and private-label customers in comparing the requested WX02 configuration with the available EMC test evidence and identifying where updated documentation or additional testing may be necessary.

Related Certifications & Resources

Find CE, FCC, RoHS and related compliance records for QBH borescopes, pipe inspection cameras, diagnostic tools and cleaning equipment. Select your product family, then check the documents available for your exact model and configuration.

US20 engine inspection borescope camera Borescope Magnification camera

Industrial & Automotive Borescopes

CE, FCC and model-specific records

AH100 Video Plumbing Inspection Sewer Camera Self-Leveling 9 HD Plumbing Pipe Camera with Depth Marking Zoom and Adjustable Brightness LED Lights Ideal for Drain Pipes Wells Machinery and Industrial​

Pipe Inspection Cameras

Pipe camera compliance documents

Technician using a camera-guided automotive A/C evaporator cleaning tool inside a vehicle.

A/C Evaporator Cleaning Equipment

Cleaning equipment certifications

Brake Fluid Moisture Tester

Automotive Diagnostic Tools

Tester and diagnostic tool records

Shenzhen Yonghengfeng SYID Official SGS ISO9001 B2B Certificate QBH borescope Specialist

ISO 9001:2015 Quality Management

SGS-certified manufacturing quality system

Eight conformity certificates and test report covers displayed in two rows.

All Product Certifications

Browse all available document families

Need Compliance Documents for Your OEM Project?

Tell us your product model, target market and required configuration. Our team can help confirm the available certification records and supporting documentation.